THE DP50RB DIARIES

The Dp50rb Diaries

The Dp50rb Diaries

Blog Article

Support 4D probe; identify the probe through the ID code; switch the 4D generate signal by way of the  electrical relay to create the 4D probe function Ordinarily. 4.2.two Primary board The most crucial board could be divided into two components: entrance-conclude of the principle board and back-end of the most crucial board.

Dengan obshape baru yang cerdas dan desain layar penuh, mobilitas yang ditingkatkan, dan pengoperasian yang lebih nyaman, sistem yang andal dan terjangkau ini akan meningkatkan praktik umum dan sangat cocok untuk berbagai kebutuhan klinis.

Assessing people in these days’s demanding ecosystem needs impressive technologies that enables clinicians to create brief and self-confident diagnoses. The flexibility of your DP-fifty expands your scientific utility while helping to boost affected person treatment.

The person is just not allowed to open the addresses and panel from the method, neither Notice: system disassemble is permitted. To make sure the program functionality and safety, only Mindray engineers or engineers licensed by Mindray can perform maintenance.

Permits use of multiple scanned angles to form a single graphic, leading to enhanced distinction resolution and improved visualization

Site 145 Clear control panel Equipment: dry delicate fabric, gentle soapy drinking water  Technique:  Use dry tender cloth to wash the floor in the process. In the event the system is soiled, moisten the tender cloth with delicate soapy h2o and wipe off any stains. Use dry tender cloth to eliminate any humidity and permit all hard surfaces to completely air-dry. Web site 146: Clean up The Peripherals

Discover greater diagnostic details by means of prolonged watch of the anatomical framework on all linear probes

The DP-fifty Expert is undoubtedly an ground breaking, higher-general performance Ultrasound System engineered that can assist you receive the insights you'll need. The System’s potent motor and significant-pace processing provide remarkable image quality and a complete information and facts administration Answer.

This manual might referring to facts secured by copyright or patents and won't Express any license under the patent legal rights or copyright of Mindray, or of Many others. Site nine: Assertion

The chapter supplies the tactic to verify most important functionality and functionality of solution. This is only useful for reference, not preventive execution. Perform checking and testing of the section shall be carried out by Mindray support engineers plus the consumer jointly. Site 66: Basic Test

Cookies are important to the proper operating of the site. To boost your experience, we use cookies to keep in mind log-in information and supply protected log-in, accumulate statistics to optimize web page functionality, and produce content tailor-made to the interests.

Be aware: Prior to inserting the connector in to the probe port, inspect the connector pin. If the pin is bent, don't use the probe till it's been inspected / fixed / changed. Setting up Peripherals For the products on the supported peripherals, remember to check with “two.

Soon after changing the CPU module, important file should be generated Once more based on the new MAC address and composed into HDD with the equipment. Or else, the configuration functionality on the solution might be misplaced. After taking away the CPU module, Get rid of panhead screws with washers (twelve M3X6) set on the primary device box, you normally takes from the board. Website page 118 Figure 8-29 Disassemble the User interface Assembly (one) Keep the higher edge of user interface assembly, and open up the control panel. Determine eight-30 Disassemble the Control Panel Dp50rb login Assembly (two) Just after getting rid of just one countersunk head self-tapping screw PT3X10 fastened about the user interface and take out the plug with the keyboard and the key unit connecting cables, you could possibly remove the control panel assembly.

Effectiveness Check 5.5.1 Check Approach Resolution Detection depth Geometric Placement Precision Blackout spot exam Report the Examination photographs five.5.two Exam Written content The impression used here is only for reference, stick to the picture outcome in the actual Take note: situation. Necessities: Display: set the contrast and brightness at the clinical software price (or perhaps the default standing) Operation environment: dark home, simulating the clinical application environment. Website page 76 In affliction the transverse resolution tests targets are horizontally displayed, report the negligible distance of two targets which can be Plainly recognized. Repeat the operation earlier mentioned with the transverse resolution testing targets at other depths. As shown in determine under. Axial resolution ... Web page 77 When using the convex probe, retain the transverse resolution screening targets to notice: be displayed close to the midline. When using a linear probe with steer function, tend not to turn on the steer purpose when perform the transverse resolution test. Zoom within the location the place the targets Positioned if important. The diameter on the target stage at a particular depth is equal to the transverse resolution with the depth. Page seventy eight 5.

Mindray respects your privateness. We use cookies for many different applications, such as Web page operation, enhancing your working experience of our website, creating integration with social media and helping goal our marketing.

5.2.three Geometric positioning accuracy Longitudinal geometric positioning precision  Check Stage: Do changes as the best way in testing the most depth. Report the space by 20mm Every phase around the longitudinal targets line using the measurement caliper; Decide on the value with the best mistake (to 20mm), compute the precision utilizing the formulation underneath The measurement caliper need to be positioned on the higher fringe of the focus on, Observe:... Web site seventy nine Transverse geometric positioning accuracy  Test Step: Go over the scan surface area with the phantom with h2o or few gel, Carefully contact the probe with the scan area Change the depth, creating the transverse targets to become exhibited while in the picture. Modify the main focus position for being posited beside the transverse targets (the standard is just not very clear) Regulate parameters like obtain, TGC, generating Each and every transverse targets to generally be Obviously shown. Web site eighty five.5.two.four Blackout Place Test Stage: Deal with the scan area from the phantom with h2o or pair gel, Carefully contact the probe Together with the scan floor Change the depth at a decrease worth, and established the main focus at the nearest place to the scan area. Lessen the value of parameters like AP, Attain till the background sound just may be noticed. Web page 81: Software package Up grade And Maintenance